Description: packing:1pcs control board DZX2.2P with Capacitor and waterproof cover.(Please tell me whether you need 220V or 110V) Electrical Diagram Explanations and InstructionsAll the electrical connections are done before delivery, and please don't change itrandomly. The necessity is connect the power and grounding connection. Explanationsand instructions for the main functions and interfaces as following (from left to right):7.1. Up limit/down limit relay output interface:This interface is for up limit (or down limit) relay output (no power, switch signal),system can get the signal of boom position from this interface.7.2. RS485 communication interface:This interface is for connecting the PC serial port via UTP-unshielded twisted pair,RS485-RS232 convertor, or RS485-USB convertor. Realize computer control thebarrier gate, and oversee the status of barrier gate according to the communicationprotocol. Address can be set by setting menu.7.3. Photocell and loop detector interface:The left 2 ports is for DC 12V power output, can provide power for photocell (currencyless than 0.5A); the right 3 ports are photocell signal input, loop detector signal inputand COM. The dry contact signal NO and COM of the photocell receiver, connecting to“Photocell signal input” and “COM” interfaces of the control board. The dry contactsignal NO and COM of the loop detector output, connecting to “Loop detector signalinput” and “COM” interfaces of the control board.7.4. Wire control signal input interface:This interface is dry contact input signal, UP (or DOWN, or STOP) connect with“COM”, the control board will response accordingly. User can use this interface toconnect IC card system or parking system, and it can also connect button switch tocontrol the barrier. Main control board wire control drive requirements, please refer toAppendix D. 7.5. Red/Green Traffic Interface:This interface is no power, same as switch, “COM” need to connect with correspondingpower of the R&G light. When boom falling down to horizontal position, red light willkeep lighting; when boom lifting up to vertical position, green light will keep lighting.During the boom falling down or lifting up, the red light will keep lighting (factorydefault), and can also set the red and green light be flashing alternately. Setting method:Pressing “SET” and “QUIT” button (no loose), then power on, the digital tube displays0F (means the red light will keep lighting during boom falling down or lifting up), or 0n(means the red and green light be flashing alternately). Loose these two button, you canchoose 0F or 0n by pressing "SET" button, then press “QUIT”, set well.7.6. Function Setting7.6.1. Auto-Closing Function Setting:When the boom open to the up limit position, start countdown according to the set time,after countdown completed, the boom will be auto-closing.Setting method as following: in limit position or stop status, long press “SET” buttonfor 3 seconds, greening setting indicator lighting, entering to setting status (the samebelow), “Auto-closing” indicator lighting, digital tube displays the current settingstatus. “OF” means the auto-closing function is off. Press and button to set the time(seconds), the time can be set as 3~60s. After setting well, press “QUIT” button to exitthe setting, coming back to working status.When the boom open to up limit position, “Auto-closing” indicator lighting, at the sametime, the digital tube displays countdown time, after countdown completed, the boomwill be auto-closing.In the countdown process, if there is up or loop detector signal, main control board willwait for the signal to disappear, then will be countdown again. If there is stop signal,this auto-closing will end; next time, when the boom open to up limit position, the auto-closing will restart. If there is down signal, boom will fall down directly.7.6.2. Auto-Reversing Function Setting:When the boom meets obstacle during falling down, it will auto-reverse (lift up), at thesame time, “Block” indicator lighting and the buzzer sounding “di-di”, user can adjustthe force of meeting obstacle or close auto-reversing function.Setting method as following: entering to setting status (same as above), press “SET”button until “Block” indicator lighting, digital tube will display the force of meetingobstacle, as following:b0 is closing auto-reversing function;b1 is lightest force;b2 is light force;b3 is middle force;b4 is great force.Press and button to set the force. After setting well, press “QUIT” button to exit thesetting, coming back to working status.7.6.3. Counting Function Setting:When the motorcade pass the barrier, there will be many up signal input, the maincontrol board will record and show the numbers. And when the car passes the loopone by one, it will minus one by one, when it become zero, the boom will be auto-closing.Setting method as following: entering to setting status (same as above), press “SET”button until “Count” indicator lighting, the digital tube will display on (means openthe counting function) or oF (means close the counting function), and you canchoose open or close by pressing or button. After setting well, press “QUIT”button to exit the setting, coming back to working status.When counting function is on, and the up signal of wire control is over 2 times, the“Count” indicator lighting, at the same time, the digital tube will display the numberof signal input. When the boom opens to up limit position, the number will becleared up by pressing “STOP” button; and the number will be cleared up and boomwill fall down by pressing “DOWN” button. It couldn't count if press “UP” buttonof the remote controller.In order to improve the traffic passing efficiency, it is better to open auto-closing andcounting functions at the same time for license plate recognition system and thelarge traffic flow entrance and exit.7.6.4. RS485 Communication Function Setting:Setting method of the address code as following: entering to setting status (same asabove), press “SET” button until the indicator of RS485 interface lighting, thedigital tube will display 0F, means RS485 is off, you can press ot button toopen RS485 and choose the address code from 1 to 99 (in the command table,“Open” command supports counting function).8. Common Malfunction and Solutions8.1. The boom moves a little and then stops, when rising and falling .8.1.1. Check up if DIP 1 sets correctly.8.2. The boom falls down normally, and need to press “UP” button for many times, thencan lift up to limit position.8.2.1. Readjust the balance spring.8.3. For 3s barrier gate, sometimes the boom lifts up with slow response.8.3.1. DIP 3 down, and DIP 4 up for 3s/1.8s barrier.8.4. There is block on 1s barrier gate, or shaking seriously on 3s or 6s barrier gate.8.4.1. Check up if DIP 3 and DIP 4 set correctly.8.5. There is big noise on 1s barrier gate.8.5.1. Check up if DIP 2 sets correctly. DIP 2 down is for 220V motor, DIP 2 up is for 110Vmotor.8.6. When power on, press “UP” or “DOWN” button, there is no reaction on the boom.8.6.1. Check up the power supply and the fuse.8.6.2. Check up if the remote controller matches radio receiver; or check up if the batteryinside lack of power.8.6.3. Check up if there is co-channel interference, and press the buttons on the control boardto check if can work.8.6.4. Check up if the external protection circuit was in failure or in the protectionstatus. Check up if the indicator of photocell and loop detector are lighting. Re-power,check up if the digital tube has the instructions as below, if has means the control boarddetects the corresponding signal is at work, need to exclude the signal, and then canwork normally.L1: Boom stop signal of wire control; L2: Boom down signal of wire control;L3: Boom up signal of wire control; L4: Loop detector signal;L5: Photocell signal; L6: Boom stop signal from remote control;L7: Boom down signal of remote control; L8: Boom up signal of remote control.8.7. Fault code description of digital tube on control board:E1: Main control board hardware failure (influences 1s barrier with crenate type limitswitch)E2: Current is abnormal (may influence auto-reversing function)E3: Not detected the current of motorE4: DCT board voltage is abnormal, when connect with DCT boardE5: Crenate type limit switch connect wrongE6: Running time timeout protection
Price: 59.9 USD
Location: shenzhen
End Time: 2024-12-24T08:08:42.000Z
Shipping Cost: 14.9 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Unbranded