Miss Selfridge

Topcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-Free

Description: Topcon TRC-NW8 Non-Myd Retinal Camera with computer and Imagenet 5 Software (Pre-Owned)This unit does Color and Red Free exams. With a differentiated infrastructure and a highly qualified team, composed of technicians and engineers trained in accordance with the highest standards required by manufacturers, SEVEN EOS is committed to excellence, development and continuous evolution of its services. Excellent Cosmetic condition! (no scratches)Excellent Body condition! (no dents/scratches)Very tiny cosmetic signs may be visible when viewed very closely Fully Functional Condition! Exceeds 80% of service lifeThis unit is in excellent mechanical and cosmetic condition - RENEWED - What does it include: - One year Warranty in USA (no additional cost) - Computer (desktop or laptop. Your preference must be specified at time of purchase) - Windows 10 and Imagenet 5 Software - Keyboard & Mouse - Manual on USB drive - Professional packing True Optical Red Free Photography:Topcon has developed an innovative feature on its TRC-NW8: True Optical red free capability with an actual red free filter. This feature allows for high resolution red-free image acquisition that is clearer than digitally enhanced images from color-only image systems. Auto Small Pupil Detection:A common problem is patients with small pupils and when mydriatic drops cannot be used the “small Pupil” (min 3.3mm) option within the TRC-NW8 allows you to still be able to get a shot. Quality of Image is Crucial as well as durability:With these important requirements Topcon did not hesitate in deciding in which manufacture it would use for its camera supplier. Nikon probably has the largest reputation when it comes to digital SLR cameras and is used by most of the worlds’ press for a very good reason. Therefore you have no need to worry that your TRC-NW8 will ever be compromised by the digital SLR in terms of quality of the image or durability. Lower Flash Intensity:Topcon has always endeavored to keep flash levels as low as possible while at the same time ensuring that good exposure images are achieved. The TRC-NW8 is no exception here, but with greater control of the CCD Camera, optimum exposure can be achieved each and every time. Aesthetic Design:In designing the new TRC-NW8 a lot of attention has been spent on the general appearance of the unit with the finest finish and also on the ergonomics. What was clear when you sit down at the camera is how logical everything is and not cluttered by many different cables. The TRC-NW8 has a unique way of eliminating connecting cables and gives the operator a clutter free environment. Fixation Target:In line with the requirements for Diabetic screening when the fixation target mode is set at DCF (“D” is for center of the optic disc, “C” is for the central Macula and “F” is for center of Fovea), the internal fixation will move one by one in the proper position that can be helpful in diagnosis such as glaucoma and diabetes. So Simple To Use:Easy Alignment, Auto Focus and Auto Shoot:Alignment could not be simpler with the New TRC-NW8. Crucially the operator is still in control however with the very latest in alignment aids the process of getting a sharp focused image time after time could not be easier. Auto focus:This is a new feature of the TRC-NW8 which allows the operator to choose to have Auto Focus facility. This can be great help when trying to photograph difficult subjects or patients with high degree of accommodation. Auto Focus allows for a sharp image every time. Auto Shoot: The TRC-NW8 has the option for Auto Shoot which is of great benefit to the operator as if monitors when all parameters are correct and takes the picture. This rapidly speeds up the capture process and is of great benefit when photographing patients who have problems fixating. The TRC-NW8 IMAGEnet High Resolution Non-Mydriatic Capture System (Telemedicine Capable) combines IMAGEnet® Lite, the recognized standard in fundus imaging telemedicine software, with the Topcon TRC-NW8 automated non-mydriatic retinal camera to provide an easy to use telemedicine color fundus screening package. Specifications: Angle of Coverage - 45 degrees Working Distance - 40.7 mm Pupil Size – 4.0 mm or Larger OR 3.3mm or more the small pupil diaphragm is used Auxiliary Functions - Auto Focus Internal Fixation Target – Center / Periphery, Right/Left Eye Auto detection and Optional position presetting function Dimensions: 272mm W X 505mm D X 530mm H Weight: 24.5 KG Power Source: 50/60Hz, Voltage AC110 Order/Payment Policy:We accept payment through PayPal. Payment is expected within 48 hours from the end of auction. After 48 hours a Non-Payment Case will be opened automatically by eBay.By placing an order, you implicitly agree to all of our terms and policies.We ship only to the verified PayPal billing address. Unverified addresses will delay processing your order. Shipping Policy:Orders are processed and shipped Monday through Friday. All orders will be processed and shipped within 3 business day from receipt of payment. Our Shipping cutoff is at 2 pm PST.Tracking will be posted to eBay as soon as the item ships.For any lost or stolen packages that show as "delivered" according to the tracking or confirmation information. Contact the carrier for further help with delivery issues.Shipping options are shown on the item page in the shipping calculator. We currently offer FedEx and USPS on most orders. Return Policy:All products except "consumables eg lamps, batteries, everything for parts or repair items", unless otherwise noted, have a 14 day Dead on Arrival warranty. If your item is not in working condition upon arrival, it may be returned for a replacement within 14 days of the product shipping date.Our warranty does not include missing accessories not declared in our ad or in the photo, etc.To return an item, contact us and request the return of the order.All returned products must be 100% complete in original packaging, in resalable condition and include manuals, warranty cards and any other accessories.The customer is solely responsible for shipping the product back to us. Local Pick Customers can pick up their order locally from our warehouse. After payment is received, we will contact you with the location and available pick-up times. Please bring a photo ID and a copy of your application. Warranty and Liability Policy:Our products are designed for users who are familiar with their equipment, medical and laboratory hardware. Some products we sell may have their warranty voided if improper installation is found. Our liability is limited to the price of the product. Transport, installation and training are not included. Request a quote if needed. If you have a problem?Before leaving neutral or negative feedback, please email us. ALL issues can usually be resolved to your satisfaction quickly and efficiently by communicating with us. We can correct most errors and pride ourselves on having 100% satisfied customers. Thanks again for shopping with us. WE SHIP WORLDWIDE! Please email or message us for an international quote.

Price: 8899 USD

Location: Lutz, Florida

End Time: 2024-02-06T04:59:37.000Z

Shipping Cost: N/A USD

Product Images

Topcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-FreeTopcon TRC-NW8 Non-Myd Retinal Camera with Imagenet 5 Software Color/Red-Free

Item Specifics

Return shipping will be paid by: Buyer

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money Back

Brand: Topcon

Country/Region of Manufacture: Japan

Fundus Camera Type: Non-Mydriatic

Recommended

ZOMBIE TRAMP #56B NYCC Wednesday Addams By Karych Ltd 100 NM W/Top Loader
ZOMBIE TRAMP #56B NYCC Wednesday Addams By Karych Ltd 100 NM W/Top Loader

$70.00

View Details
TOPCON  RL-60B
TOPCON RL-60B

$310.00

View Details
Beseler Topcon Super-D Camera & Beseler Topcon View Finder EXCELLENT CONDITION
Beseler Topcon Super-D Camera & Beseler Topcon View Finder EXCELLENT CONDITION

$159.99

View Details
Topcon GT-1003 3” Robotic Total Station (great condition)
Topcon GT-1003 3” Robotic Total Station (great condition)

$6989.75

View Details
Topcon Horseman 980 Field Camera Body , 90mm f 5.6 *621340
Topcon Horseman 980 Field Camera Body , 90mm f 5.6 *621340

$178.99

View Details
Topcon RE Auto-Topcor 10cm F2.8 Telephoto Prime Lens W/ Topcor Plastic Lens Case
Topcon RE Auto-Topcor 10cm F2.8 Telephoto Prime Lens W/ Topcor Plastic Lens Case

$220.00

View Details
Topcon RL-H5A Rotary Laser with LS-80X Receiver with Dome-head Tripod & 8ft Rod
Topcon RL-H5A Rotary Laser with LS-80X Receiver with Dome-head Tripod & 8ft Rod

$749.00

View Details
Topcon Wink Mirror S Tokyo Kogaku
Topcon Wink Mirror S Tokyo Kogaku

$10.00

View Details
TOPCON GRS-1 FIELD CONTROLLER RECEIVER
TOPCON GRS-1 FIELD CONTROLLER RECEIVER

$189.95

View Details
Topcon DT-104 Digital Theodolite w/ Case
Topcon DT-104 Digital Theodolite w/ Case

$722.50

View Details