Description: HomeView All ListingsStore PoliciesNewsletterFeedbackContact Us Store Categories Aluminum URD Cable Aluminum Service Drop Cable Aluminum XHHW-2 Wire Aluminum XLP USE-2 Aluminum SER Alpha Wire Belden Cable Bus Drop Cable Copper SER Copper XHHW-2 Wire Copper XLP USE-2 Copper THHN THWN-2 Diesel Locomotive Cable Festoon Cable Fire Alarm Cable High Temperature Wire Jumper Cable Type G & GG-C Thermostat Cable Power Cable SOOW NM-B Wire Security Fire Alarm Cable SIS Switchboard Wire Solar Photovoltaic PV Wire Stage Lighting Cable Submersible Pump Cable Tray Cable Type W Power Cable UF-B Cable Welding Cable CMP TMC2-150A162 Aluminum 1-1/2'' NPT Thread Armored Cable Gland (Jacket Diameter 1.30'' to 1.62'') Click Thumbnails to Enlarge APPLICATION • CMP TMC2-150A162 is Aluminum Globally Approved, Hazardous (Classified) Location Cable Gland. DESCRIPTION • Simplified two part design • Compact slim profile • Independent sealing and armor clamping • Simple, sequential installation process • No disassembly required • Equipment interface O-ring face seal as standard • Hub not required • Low Impedance Copper Plated Stainless Steel 360° Grounding Spring • -60˚C to +110˚C (-76˚F to +230˚F) • Globally marked, cCSAus, IECEx and ATEX TECHNICAL SPECIFICATIONS & STANDARDS • Design Specification: BS 6121:Part 1:1989, IEC 62444, EN 62444 • Enclosure Protection: IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only • Mechanical Classifications*: Impact = Level 8, Retention = Class D • ATEX Certificate: CML 18ATEX1335X • Code of Protection: Ex II 2G 1D, Ex eb IIC Gb, Ex ta IIIC Da • Compliance Standards: EN 60079-0,7 • IECEx Certificate: IECEx CML 18.0192X • Code of Protection: Ex eb IIC Gb, Ex ta IIIC Da • Compliance Standards: IEC 60079-0,7,31 • cCSAus Certificate: 2194053 • CSAus Code of Protection: Class II, Div 1 and 2, Groups E, F, and G; Class III, Div 1 and 2; Encl. Type 4X; Ex e II; Class I, Zone 1, AEx e II; AEx ta IIIC • cCSA Code of Protection: Class I, Div 2, Groups A, B, C, and D; Class II, Div 1 and 2, Groups E, F, and G; Class III, Div 1 and 2; Encl. Type 4X; Ex e II; Class I, Zone 1, AEx e II; AEx ta IIIC • Compliance Standards: CAN/CSA-C22.2 No 0-10,18-04,25-1966,30-M1986,174-M1984,94-M91, ANSI/UL 2225, ANSI/UL 50, ANSI/UL 514B, CAN/CSA-E61241-1-1, CAN/CSA-C22.2 No.60079-0:07,7:07 • ECAS Certificate: 20-02-06425 • EAC Certificate (Formerly GOST R, K & B): TC RU C-GB.AA87.B.00487 • Code of Protection: 1Ex e IIC GB X, Ex ta IIIC Da X, IP66 • UkrSEPRO: CU 19.0371X • CCOE / PESO (India) Certificate: Ex e: P533772 • RETIE Approval: 03866 • Marine Approvals: LRS: 01/00172, DNV: TAE00000Y, ABS: 20-2022051-PDA, BV: 43180/A1BV • CCC Certificate: 2020322313003284 • Ingress Protection Rating: Type 4X & IP66 • Cable Type: Corrugated & Interlocked Metal Clad Armor (MC) or TECK90, Continuously Welded Metal Clad Armor (MC-HL), ACIC-HL, ACWU90-HL, RC90-HL, RA90-HL • Armor Clamping: Low Impedance Copper Plated Stainless Steel 360° Grounding Spring • Jacket Sealing Technique: CMP Load Retention Seal • Sealing Area(s): Cable Outer Jacket • Seal Material: CMP SOLO LSF Halogen Free Thermoset Elastomer • Cable Gland Material: Copper Free (<0.4%) Aluminum PRODUCT SPECIFICATIONS Material Aluminum Entry Thread ‘C’ (NPT Option) 1-1/2" Minimum Thread Length 'E' 1.03" Cable Armor Diameter 'A' (Armor Stop In) (Min) 1.22" Cable Armor Diameter 'A' (Armor Stop In) (Max) 1.42" Cable Armor Diameter 'A' (Armor Stop Out) (Min) 1.42'' Cable Armor Diameter 'A' (Armor Stop Out) (Max) 1.50'' Cable Jacket Diameter 'B' (Min) 1.30'' Cable Jacket Diameter 'B' (Max) 1.62" Thru Bore 'G' 1.38" Across Flats ‘D’ (Max) 2.36" Across Corners ‘D’ (Max) 2.60" Nominal Assembly Length 'F' 3.59'' Shroud PVC18 Approx Weight Aluminum (oz) 8.82 CUT TO LENGTH • If you are looking for any Custom Lengths? Please feel free to contact us. We Can do all Cut Lengths. OTHER VALUE ADDED SERVICES • Expedited Shipping • Cut to Length Paralleling • Color Striping & Dyeing • Reel Lagging • Special Labeling & Packages Shipping • Need the wire fast? Ask about our expedited shipping to get it to you on time. Signature required for all deliveries. Please note eBay's delivery dates are only estimates actual delivery dates may be faster or longer, please message us for exact delivery times.*** Payment & Returns • All returns must be made within 30 days from the date of purchase or they will not be accepted. Nassau National Cable does not cover re-delivery fees, extraneous shipping expenses or change of address fees after shipping*** Feedback • Feedback will be left as soon as feedback is left for us.
Price: 110 USD
Location: Carlyle, Illinois
End Time: 2024-09-06T12:28:24.000Z
Shipping Cost: 15 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: CMP
Type: Cable Gland
Termination Type: Threaded
MPN: TMC2150A162
Material: Aluminum
Country/Region of Manufacture: United States