Description: If a Mars MEI series 2000 validator is installed in a machine with pulse interface and the validator is giving a 2 blink error code bills will not be accepted. The issues is the VMC or single price changer is not enabling the validator. The issue could also be the harness with the 18-position connector that attaches to the validator. This jumper will connect directly to the validator in place of the harness from the VNC or single price coin changer. The validator will then accept bill. Once installed you will know the validator is working and can then fix the issue in the machine,The way the VMC enables the validator varies by machine make and model – the information on how this works is typically explained in the owner’s manual of the machine.