Description: CONTEC8000G ECG Workstation 12 Lead EKG Machine Recorder PC Based SW Analyzer CE IntroductionThe device acquires functions that including synchronous sampling of conventional 12-lead ECG data and 3-lead vector ECG data, various forms of analysis and diagnosis, report output and other functions. As an integrated ECG analysis system, the device can reflect user's heart movement timely and accurately. It is applicable for ECG examination in medical and health institutions, providing accurate and reliable basis for diagnosis. Features1.Compact and portable design for Recorder, support both Wilson and Frank lead system, with lead-off indicator..2.Adopt real-time sampling, display and storage mode, with functions such as QRS waveform analyzing in real-time, HR calculation and real-time printing, as well as multiple filter methods to avoid from baseline drift and interference.3. Advanced ECG analysis algorithm ensures accurate auto-analyzing points and reliable auto-recognizing sort of arrhythmia, which makes the analyzing report and conclusion more valuable.4. For clear display, ECG waveform uses anti-aliasing technology; smart adjustment function of lead position solves the problem of overlapping waveform caused by baseline drift or high amplitude waveform.5. High sampling frequency (1000 Hz) ensures correct ECG waveform without distortion. High resolution in display and printout guarantees the details of ECG waveform.6. With dozens of sync and continuous display/print modes, including 6x2, 3x4, 3x4+2, etc. Auxiliary tool, such as superposed waveform analysis, electronic scale and editable terminology database, etc., brings much more convenient for diagnosis and clinical application.7. Multiple analysis function, including: conventional 12-lead ECG, Frequency Cardiogram (FCG), High Frequency ECG, QT internal dispersion analysis, Heart Rate Variability (HRV) analysis, myocardium ischemia (STLE) analysis, Heart rate turbulence (HRT) analysis, Pacing ECG analysis, Vector Cardiogram (VCG), Time Vector Cardiogram (TVCG) and SAECG, etc.8. The "shortcut print" function can preview or print the whole analysis reports, and save them in PC with multimedia format (BMP, PNG, PDF or JPG format) according to factual need9. Support calling external procedures to obtain patient information of unknown origin, exporting HL7 aECG standard format ECG data, printing electronic report and sending notice to external procedure, convenience for systems docking with hospital HIS, PACS and others. PerformanceHR display range: 30 bpm~300 bpm, error: 30 bpm~100 bpm, ±1b pm; 100 bpm~ 300 bpm, ±1%.Sampling frequency of ECG signal input: 32 k HzSampling frequency of waveform data processing: 1 kHzSampling accuracy: 24 bitsLead: Standard 12 leadsDynamic range: ±5 mVGain control: continuous variation is availableGain switch: When the gain is changing, there is indication for the recording output.Gain stability: After startup for 1 minute, the gain variation per minute shall be no more than 0.33%. The total variation within 1 hour of the constant gain at each level shall be no more than ±3%.Time base accuracy: within 0.2 s~2.0 s, the permitted error shall be no more than ±5%.Channel width: the display width of each channel shall be no less than 40mm.Track width: <1 mmSystem error: ±5%Lead weight factor: accuracy within ±5%Calibration voltage: 1 mV, deviation within ±5%Input impedance: >2.5 MΩ; >50 MΩ (10 Hz)Patient-electrode DC current: <1 μASystem noise: ≤15 μVp-pCMRR: >105 dBAmplitude-frequency characteristic:Rated input amplitude Input frequency and waveform Relative output response1.0 0.67 Hz ~ 40 Hz, sinusoidal ±10%a0.5 40 Hz ~ 100 Hz, sinusoidal +10%, -30%a0.25 100 Hz ~ 150 Hz, sinusoidal +10%, -30%a0.5 150 Hz ~ 500 Hz, sinusoidal +10%, -100%a1.5 ≤1 Hz ,200 ms, triangular +0%, -10%ba Output relative to 10 Hzb Output relative to 200 msGain setting and accuracy: three levels: 5, 10, 20 mm/mV, accuracy: ±5%Time base: 12.5 mm/s, 25 mm/s, 50 mm/sSafety type: Class II, Type CF with defibrillation protection AccessoriesGround wire 1pcPatch cord 2pcsData transmission line 1pcLead cable 1pcLimb electrode clamp 1 set (4pcs)Chest electrode 1 set (6pcs)User manual 1pclead wire clip 1pc(2pcs)software 1 pc Physical CharacteristicOperational environmenta) Environment temperature: 5℃~ 40℃b) Relative humidity: 25%~ 95% (no condensation)c) Power supply: USB DC 5Vd) Atmospheric pressure: 700hPa~1060hPaStorage environmenta) Environment temperature: -40℃~+55℃b) Relative humidity: ≤95%HRc) Atmospheric pressure: 500hPa~1060hPa CertificationCFDA certificate ,CMC certificate and CE certificate. Buy Safe Product The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item. Shipment 1. We will ship the item within 48 hours after receiving your payment, please kindly leave your detail shipping address and telephone number, both are very important for the shipment,thank you.2.All items will be shipped to buy's ebay address. Please check your ebay address is right.3.The item will be declared as lower value for shipping only.We'd like to cooperate with you and declare the value as your request,so that it is easier for you to clear the customs in your country.4. If you haven't received the item after 2 weeks of your payment, please contact me immediately! Terms Of Sale We offer 60 days return policy. 100% satisfaction is our goal! 1.All items are brand new ,with 2 year warranty. 2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the shipment. 3.We will refund the money to you when we get the returned item or make a replacement for you.4. All returned items must be returned with it's original packaging and accessories. Customer is responsible for shipping charges on returned items. 5.Sometimes there's some delay for the delivery of your package,Please kindly contact us for more information.Please don't open any cases nor return requests on both ebay and paypal,and please don't leave me any negative nor neutral feedback on ebay.I will try my best to give you a satisfied solution. About Us CONTEC Medical System-----Focusing on research, manufacture and distribution of medical equipment, CONTEC Medical System was founded in 1992 as a professional medical equipment producer. CONTEC was dedicating to research, manufacture and distribution of medical devices, now we have developed more than 20-category products contained Pulse Oximeter, Sphygmomanometer, ECG, EEG, Ultrasound Equipment, Fetal Doppler,Patient Monitor and Image Equipment,etc Our products have passed CE, FDA and COS/VIOS certificate. At present, CONTEC produces and distributes more than 2000000 products per year, which were distributed to over 200 countries and regions. Contact Us We are Professional Manufacturer--CONTEC MEDICAL SYSTEMS CO.,LTDLooking forward to establishing a successful business relationship with you.Address(CN): NO.112 Qinhuang West Avenue,E&T Development zone,Qinhuangdao,China Address(US):1440 CHASE AVE ,ELK GROVE VILLAGE IL 60007-4825,United States
Price: 277.99 USD
Location: qinhuangdao,hebei
End Time: 2024-07-27T03:42:50.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Return policy details:
Brand: CONTEC
Number of Channels: 12
ECG & EKG Machine Type: ECG Event Recorder
MPN: 69450401