Description: HTML clipboard Vacuum Exposure Unit 110V ASC6050ZK Precise Vacuum UV Exposure Unit is equipped with special UV lamps and auxiliary vacuum suction device. After putting the screens and well printed transparency film on the glass, close its cover and let it work after set the needed vacuum and exposure time, then it will make the screens and transparency film close on the glass tightly by evacuating the air of the vacuum charmer emerging from the rubber blanket. When the set time is up, it will deflate automatically, and then the exposure is finished. Please cut off the power supply. Working principle Screen printing screens are coated with a light sensitive emulsion using a scoop coater. When the emulsion is dry, place your image with a positive print on the screen. Once you burn the screen, the emulsion that did not get any UV will wash out of the screen exposing the tiny pin holes. The surrounding areas that were exposed to UV will be cured. Hence the ink will pass through screen onto your substrate. Special Tips The vacuum pumping area (sizes of the rubber blanket) is 23.6”*27.6” (60*70cm), but the optimum screen exposing size is within 19.7”*23.6”*1.6” (50*60*4cm) by the outer sizes. (If your screen is oversized, please buy cautiously!) Operation Instructions 1. Connect the power supply; Turn on the switch of “POWER”; Control panels are shipped randomly 2. Set the vacuum pumping time 1) Press “VACUUM”, the left indicator light (yellow) is lit up; 2) Press “ + ” or “ – ” in the “TIME CONTROL” area to set the vacuum pumping time according to your needs. (For first-time users, please put an empty screen in the middle of the rubber inner cavity, just set 40 seconds for test; if the pointer of the vacuum gauge could reach or pass the middle of the green area, that’s ok. If not, please extend the time and test again until having reached the requirement. 3. Set the exposure time 1) Press “EXPOSURE”, the left indicator light (red) is lit up; 2) Press “ + ” or “ – ” in the “TIME CONTROL” area to set the exposure time according to your needs. (Exposure time varies according to the coated photosensitive emulsion. Please just set 300 seconds for test and then reset a suitable time according to the exposure effect.) 4. Once finished the above settings, you could start exposure just as follows 1) Put the screens coated with photosensitive emulsion and the printed transparency film on the glass. 2) Put the air suction pipe in to the screen; 3) Close the cover and click the “START” button, then it will vacuum pump and expose automatically according to the settings; 4) When the set time is up, it will deflate automatically; Open the cover and exposure is finished. Please just cut off the power supply 5. Functions of other keys 1) “RESET” for cancelling the previous settings: if you want to reset the vacuum / exposure time, just press “VACUUM” / “EXPOSURE” and the left indicator light is lit up; Then press “RESET” and the original settings will turn to “ 0 ”; Next, you could set according to your needs. 2) “BACK” for stop working: if you want to stop vacuum pumping or exposure, just press the “BACK” button, that’s ok. Breakdown Maintenance 1. If the digit was not displayed once turned on the switch a. Please check whether the power supply is good or not b. Please check whether the bottom fuse wire is loose, burned-out or not 2. If the vacuum pump didn’t work after putting the screen on the glass, closing the cover and pressing the “STRAT” button: Please check whether the leading wire of the vacuum pump is well connected or not 3. If it didn’t reach the requirement even the vacuum pump works well a. please checks whether the air suction pipe is well fastened or not b. Please check whether the rubber blanket and its edgings were good and seal or not. If there were some splits on the rubber blankets or edgings, or some cracks of the edging adhesives, please fix them up with the sealing adhesive. 4. If the lamps were not lit up a. Please check whether your voltage was too low or not b. Please check whether the lamp ends were blackened or not caused by lamp ageing c. Please check whether your set exposure time was 0 second d.Please check whether the ballast was broken or not. Essential Parameters Input Voltage 110V Exposure area 23.6”*27.6” (60*70cm) Vacuum Degree -0.08Mpa Illumination Uniformity 85% Lamp Power 240W Vacuum Pump Power 60W Vacuum Time Setting Range 0-999s Exposure Time Setting Range 0-999s Machine Size 33.5”*32.5”*7.5” (85*82.5*19cm) Package size 35”*33.5”*9.8” (88*86*24.5cm) Net weight 66Lb / 30kg Gross weight 90.4Lb / 41kg Item Number:219104
Price: 658.94 USD
Location: Norcross, Georgia
End Time: 2024-08-18T04:13:46.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Breveltion
Type: Vacuum Exposure Unit
Voltage: 110 V
MPN: 219104
Material: Steel
Automation Type: Manual
Exposure Unit Type: UV